Cooling system
A cooling system must be provided on compressors in order to:
⠀
• Cool the gas after compression downstream of each compression stage.
• Cool the compression cylinders, which heat up due to contact with the compressed gas and to the friction of the moving parts.
• Cool the lubrication oil, which in turn cools all the moving mechanical parts of the compressor.
⠀
SAFE provides a water-cooled system. An air-cooled system can also be provided on request.
⠀
Water-cooled system features:
⠀
• It can be positioned outside the premises (on the forecourt or above the roof of the compressor room). It cools a water-glycol solution, which is sent to the compressor by an electric pump positioned on the same cooling system.
• It can be an ATEX version, i.e. suitable for installation in areas where presence of gas is possible (i.e. near the compressor/storage room openings when the space available does not allow the minimum distance to be respected).
• It can be configured to achieve minimal noise levels if required.
• The water-glycol solution cooled by the system on the compressor skid feeds the gas-water, oil-water heat exchangers and the cooling jackets of the compression cylinders.
⠀
|
TECHNICAL DATA SHEET |
|||
---|---|---|---|---|
Power Range |
Fans #/Φ (mm) |
Fan power (kW) |
Pump power (kW) |
Dimensions (m) - LxWxH |
22 ÷ 30 |
2x500 |
0.8 |
0.75 |
1.9x0.9x0.8 |
37 ÷ 45 |
3x500 |
2.16 |
0.75 |
2.8x0.9x0.8 |
55 ÷ 90 |
2x800 |
3.6 |
1.85 |
4x1.5x1.6 |
110 ÷ 160 |
3x800 |
5.4 |
1.85 |
5.7x1.5x1.6 |
200 |
4x800 |
14.4 |
4 |
3.3x2.5x2.2 |
250 ÷ 315 |
6x800 |
10.8 |
4 |
4.6x2.5x2.2 |
355 ÷ 400 |
8x800 |
14.4 |
4 |
3.3x2.5x2.2 |
Power based on an operating temperature of 40 °C